In a typical single-ended configuration, the analog
input signal (Figure 10a) enters the T/H amplifier stage
at the in-phase input (VIN+), while the inverted phase
input (VIN-) is reverse-terminated to GNDI with an
external 50Ω resistor. Single-ended operation allows for
an input amplitude of ±250mV. Table 3 shows a selec-
tion of input voltages and their corresponding output
codes for single-ended operation.
Differential Analog Inputs
To obtain a full-scale digital output with differential input
drive (Figure 10b), 250mVp-p must be applied between
VIN+ and VIN- (VIN+ = +125mV and VIN- = -125mV).
Midscale digital output codes (01111111 or 10000000)
occur when there is no voltage difference between
VIN+ and VIN-. For a zero-scale digital output code, the
in-phase (VIN+) input must see -125mV and the invert-
ed input (VIN-) must see +125mV. A differential input
drive is recommended for best performance. Table 4
represents a selection of differential input voltages and
their corresponding output codes.
MAX104
±5V, 1Gsps, 8-Bit ADC with
On-Chip 2.2GHz Track/Hold Amplifier
______________________________________________________________________________________ 17
Figure 10b. Differential Analog Input Signals
Table 3. Ideal Input Voltage and Output Code Results for Single-Ended Operation
0V 11111111 (full scale)+250mV
VIN-
1
OVERRANGE BITVIN+ OUTPUT CODE
0V 11111111+250mV - 1LSB 0
0V
0V
01111111
toggles
10000000
0V 0
0000001 -250mV + 1LSB 0
0V 00000000 (zero scale)-250mV 0
Comentários a estes Manuais