Note: 1. Not more than one output at a time should be shorted. Duration of short circuit test should not exceed 30 sec.
DC Characteristics
Symbol Parameter Condition Min Typ Max Units
I
LI
Input Load Current V
IN
= -0.1V to V
CC
+ 1V 10 µA
I
LO
Output Leakage
Current V
OUT
= -0.1V to V
CC
+ 0.1V
10 µA
I
CC
Power Supply
Current, Standby
V
CC
= MAX,
V
IN
= MAX,
Outputs Open
B-7, -10
Com. 125 180 mA
Ind., Mil. 125 190 mA
B-15, -25
Com. 125 180 mA
Ind., Mil. 125 190 mA
BL-15
Com. 15 30 mA
Ind., Mil. 15 30 mA
I
OS
(1)
Output Short
Circuit Current V
OUT
= 0.5V
-120 mA
V
IL
Input Low Voltage 4.5 ≤ V
CC
≤ 5.5V -0.6 0.8 V
V
IH
Input High Voltage 2.0 V
CC
+ 0.75 V
V
OL
Output Low
Voltage
V
IN
= V
IH
or V
IL
,
V
CC
= MIN
I
OL
= 16 mA Com., Ind. 0.5 V
I
OL
= 12 mA Mil. 0.5 V
I
OL
= 24 mA Com. 0.8 V
V
OH
Output High
Voltage
V
IN
= V
IH
or V
IL
,
V
CC
= MIN
I
OH
= -100 µA V
CC
- 0.3 V
I
OH
= -4.0 mA 2.4 V