16
4957E–AUTO–10/07
ATA6623/ATA6625
7.7
Load regulation
maximum
5mA < I
VCC
< 50 mA VCC VCC
load
0.5 2 % A
7.8 Output current limitation VS > 5.5V VCC I
VCCs
–200 –160 mA A
7.9 Load capacity 1 < ESR < 5 @ 100 kHz VCC C
load
1.8 10 µF D
7.10
VCC undervoltage
threshold
Referred to VCC
VS > 5.5V
VCC V
thunN
4.2 4.8 V A
7.11
Hysteresis of
undervoltage threshold
Referred to VCC
VS > 5.5V
VCC Vhys
thun
250 mV A
7.12
Ramp up time VS > 5.5V
to VCC = 5V
C
VCC
= 2.2 µF
I
load
= –5 mA at VCC
VCC T
VCC
130 300 µs A
8
LIN Bus Driver: Bus Load Conditions:
Load 1 (Small): 1 nF, 1 k; Load 2 (Large): 10 nF, 500; R
RXD
= 5 k; C
RXD
= 20 pF
10.5, 10.6 and 10.7 Specifies the Timing Parameters for Proper Operation at 20 Kbps
8.1
Driver recessive output
voltage
Load1/Load2 LIN V
BUSrec
0.9 × V
S
V
S
VA
8.2 Driver dominant voltage
V
VS
= 7V
R
load
= 500
LIN V
_LoSUP
1.2 V A
8.3 Driver dominant voltage
V
VS
= 18V
R
load
= 500
LIN V
_HiSUP
2VA
8.4 Driver dominant voltage
V
VS
= 7V
R
load
= 1000
LIN V
_LoSUP_1k
0.6 V A
8.5 Driver dominant voltage
V
VS
= 18V
R
load
= 1000
LIN V
_HiSUP_1k
0.8 V A
8.6 Pull–up resistor to V
S
The serial diode is
mandatory
LIN R
LIN
20 30 60 k A
8.7
LIN current limitation
V
BUS
= V
Batt_max
LIN I
BUS_LIM
40 120 200 mA A
8.8
Input leakage current at
the receiver including
pull-up resistor as
specified
Input Leakage current
Driver off
V
BUS
= 0V
V
Batt
= 12V
LIN I
BUS_PAS_dom
–1 –0.35 mA A
8.9
Leakage current LIN
recessive
Driver off
8V < V
Batt
< 18V
8V < V
BUS
< 18V
V
BUS
V
Batt
LIN I
BUS_PAS_rec
15 20 µA A
8.10
Leakage current when
control unit disconnected
from ground.
Loss of local ground
must not affect
communication in the
residual network
GND
Device
= V
S
V
Batt
= 12V
0V < V
BUS
< 18V
LIN I
BUS_NO_gnd
–10 +0.5 +10 µA A
8.11
Node has to sustain the
current that can flow
under this condition. Bus
must remain operational
under this condition.
V
Batt
disconnected
V
SUP_Device
= GND
0V < V
BUS
< 18V
LIN I
BUS
515µAA
8. Electrical Characteristics (Continued)
5V < V
S
< 27V, –40°C < T
j
< 150°C; unless otherwise specified all values refer to GND pins.
No. Parameters Test Conditions Pin Symbol Min. Typ. Max. Unit Type*
*) Type means: A = 100% tested, B = 100% correlation tested, C = Characterized on samples, D = Design parameter