MAX7469/MAX7470
HDTV Continuously Variable
Anti-Aliasing Filters
12 _______________________________________________________________________________________
Command Byte (Write Cycle)
A write cycle begins with the bus master issuing a
START condition followed by 7 address bits (Figure 5)
and 1 write bit (R/W = 0). After successfully receiving its
address, the MAX7469/MAX7470 (slave) issue an ACK.
The slave recognizes the next byte after a successfully
received address as the command byte (Table 3).
Use the command byte to configure the MAX7469/
MAX7470. While most of the commands listed in Table
3 modify the functionality of the MAX7469/MAX7470,
some commands prepare the device for further data
transfers (see the
Control/Status Register
and
Frequency Register
sections). If the write cycle is pre-
maturely aborted, the register is not updated, and the
COMMAND BYTE:
INDIVIDUAL BIT DEFINITIONS
C7 C6 C5 C4 C3 C2 C1 C0
DESCRIPTION
00000000Enters power-down mode.
00000001
Wake-up; resumes normal operation using the frequency/status previously stored
(unless power has been cycled).
00000010Sets IN1 clamp voltage level to low.
00000011Sets IN1 clamp voltage level to high.
00000100Sets IN2 clamp voltage level to low.
00000101Sets IN2 clamp voltage level to high.
00000110Sets IN3 clamp voltage level to low.
00000111Sets IN3 clamp voltage level to high.
00001000Selects component input, color-burst filter disabled.
00001001Selects composite input, color-burst filter enabled.
00001010Selects internal sync.
00001011Selects external sync.
00001100Selects positive polarity external sync.
00001101Selects negative polarity external sync.
00001110Enables filters.
00001111Disables filters, enters bypass mode.
00010000
Resets the control/status register to the default values as described in the Control/
Status Register section. This command does not affect the frequency register.
00010001
Requests a control/status register read. The interface expects an Sr condition to
follow with address and read/write set to read so data can be driven onto the bus.
00010010Loads the frequency register with the data byte following the command byte.
00010011
Requests a frequency register read. The interface expects an Sr condition to follow
with address and read/write set to read so data can be driven onto the bus.
Table 3. Command Byte Definition