MAX5927/MAX5929
The MAX5927/MAX5929 turn off all channels if any of
the above conditions are not met. After a fault-latched
shutdown, cycle any of the ON_ inputs to unlatch and
restart all channels.
Power-Sequencing Mode
Leave MODE floating to enter power-sequencing
mode. While in power-sequencing mode, the
MAX5927/MAX5929 turn on and off each channel
depending on the state of the corresponding V
ON_
. To
turn on a given channel:
• At least one V
IN_
must exceed V
UVLO
(2.45V) for the
UVLO to startup delay (37.5ms).
• All V
IN_
must exceed V
PWRRDY
(0.95V).
• The corresponding V
ON_
must exceed V
ON,TH
(0.875V).
• No faults may be present on any channel.