MAX1774
Dual, High-Efficiency, Step-Down
Converter with Backup Battery Switchover
_______________________________________________________________________________________ 7
PARAMETER
SYMBOL
CONDITIONS
MIN MAX
UNITS
CVL, CVH REGULATORS
CVL Output Voltage V
CVL
I
CVL
= 50mA, V
CS-
= 0 2.6 3.1 V
CVL Switchover Threshold V
CS-
rising, hysteresis = 100mV typical
2.40 2.55
V
V
IN
= +4V, I
CVH
= 25mA
V
IN
- 2.8
CVH Output Voltage V
CVH
V
IN
= +12V, I
CVH
= 50mA
V
IN
- 3.65
V
V
CVL
rising
2.40 2.57
CVL Undervoltage Lockout
V
CVL
falling
2.30 2.47
V
LOW-VOLTAGE COMPARATORS
V
BKOFF
rising
0.51 0.59
Backup Regulator Shutdown
Threshold
V
BKOFF
V
BKOFF
falling
0.46 0.54
V
BKOFF Input Bias Current V
BKOFF
= +5.5V 1 µA
LBI Threshold V
LBI
V
LBI
falling, hysteresis = 50mV typical
1.17 1.23
V
DBI Threshold V
DBI
V
DBI
falling, hysteresis = 50mV typical
1.17 1.23
V
BKUP Low-Input Threshold 0.4 V
LBI, DBI Input Leakage Current V
LBI
, V
DBI
= +28V
100
nA
LBO, BKUP, ACO, MDRV
Output Low
I
SINK
= 1mA 0.4 V
LBO, BKUP, ACO, MDRV
Output Leakage Current
V
LBI
= +1.3V, V
ACI
= V
IN
= +12V, V
ACO
=
V
LBO
= V
BKUP
= +5.5V, V
MDRV
= +28V
1.0 µA
ACI Threshold V
ACI
- V
INS
, ACI falling 0.5 V
ACI Input Leakage Current V
ACI
= +1.3V
100
nA
MAIN Input Leakage Current V
INS
= +3.3V 10 µA
LOGIC INPUTS
SHDNM, SHDNC Input Low
Voltage
0.4 V
SHDNM, SHDNC Input High
Voltage
2.0 V
SHDNM, SHDNC Input Low
Current
SHDNM = SHDNC = GND -1 1 µA
SHDNC Input High Current V
SHDNC
= +5.5V 5 µA
SHDNM Input High Current V
SHDNM
= +28V 25 µA
ELECTRICAL CHARACTERISTICS (continued)
(Figure 1, V
IN
= V
INS
= +12V, V
INC
= V
CS+
= V
CS-
= +3.3V, V
CORE
= +1.8V, T
A
= -40°C to +85°C, unless otherwise noted.) (Note 2)
Note 1: This parameter is guaranteed based on the LXC P-channel current limit and the LXC N-channel valley current.
Note 2: Specifications to -40°C are guaranteed by design and not production tested.
Vista de página 6