For free samples & the latest literature: http://www.maxim-ic.com, or phone 1-800-998-8800.
For small orders, phone 408-737-7600 ext. 3468.
________________General Description
The MAX125/MAX126 are high-speed, multichannel,
14-bit data-acquisition systems (DAS) with simultane-
ous track/holds (T/Hs). These devices contain a 14-bit,
3µs, successive-approximation analog-to-digital con-
verter (ADC), a +2.5V reference, a buffered reference
input, and a bank of four simultaneous-sampling T/H
amplifiers that preserve the relative phase information
of the sampled inputs. The MAX125/MAX126 have two
multiplexed inputs for each T/H, allowing a total of eight
inputs. In addition, the converter is overvoltage tolerant
to ±17V; a fault condition on any channel will not harm
the IC. Available input ranges are ±5V (MAX125) and
±2.5V (MAX126).
An on-board sequencer converts one to four channels
per CONVST pulse. In the default mode, one T/H output
(CH1A) is converted. An interrupt signal (INT) is pro-
vided after the last conversion is complete. Convert
two, three, or four channels by reprogramming the
MAX125/MAX126 through the bidirectional parallel
interface. Once programmed, the MAX125/MAX126
continue to convert the specified number of channels
per CONVST pulse until they are reprogrammed. The
channels are converted sequentially, beginning with
CH1. The INT signal always follows the end of the last
conversion in a conversion sequence. The ADC con-
verts each assigned channel in 3µs and stores the
result in an internal 14x4 RAM. Upon completion of the
conversions, data can be accessed by applying suc-
cessive pulses to the RD pin. Four successive reads
access four data words sequentially.
The parallel interface’s data-access and bus-release
timing specifications are compatible with most popular
digital signal processors and 16-bit/32-bit microproces-
sors, so the MAX125/MAX126 conversion results can
be accessed without resorting to wait states.
________________________Applications
Multiphase Motor Control
Power-Grid Synchronization
Power-Factor Monitoring
Digital Signal Processing
Vibration and Waveform Analysis
____________________________Features
Four Simultaneous-Sampling T/H Amplifiers with
Two Multiplexed Inputs (eight single-ended inputs
total)
3µs Conversion Time per Channel
Throughput: 250ksps (1 channel)
142ksps (2 channels)
100ksps (3 channels)
76ksps (4 channels)
Input Range: ±5V (MAX125)
±2.5V (MAX126)
Fault-Protected Input Multiplexer (±17V)
±5V Supplies
Internal +2.5V or External Reference Operation
Programmable On-Board Sequencer
High-Speed Parallel DSP Interface
MAX125/MAX126
2x4-Channel, Simultaneous-Sampling
14-Bit DAS
________________________________________________________________
Maxim Integrated Products
1
19-1319; Rev 1; 1/98
PART
MAX125ACAX
MAX125BCAX 0°C to +70°C
0°C to +70°C
TEMP. RANGE PIN-PACKAGE
36 SSOP*
36 SSOP*
EVALUATION KIT
AVAILABLE
______________Ordering Information
*
Contact factory for availability.
Typical Operating Circuit appears at end of data sheet.
Pin Configuration appears at end of data sheet.
INL
(LSB)
±2
±4
MAX125AEAX -40°C to +85°C 36 SSOP* ±2
MAX125BEAX -40°C to +85°C 36 SSOP* ±4
MAX125CCAX 0°C to +70°C 36 SSOP ±4
MAX125CEAX -40°C to +85°C 36 SSOP ±4
MAX126ACAX
MAX126BCAX
MAX126CCAX 0°C to +70°C
0°C to +70°C
0°C to +70°C 36 SSOP*
36 SSOP*
36 SSOP
±2
±4
±4
MAX126AEAX -40°C to +85°C 36 SSOP* ±2
MAX126BEAX -40°C to +85°C 36 SSOP* ±4
MAX126CEAX -40°C to +85°C 36 SSOP ±4
Vista de página 0
1 2 3 4 5 6 ... 15 16

Resumo do Conteúdo

Página 1 - 14-Bit DAS

For free samples & the latest literature: http://www.maxim-ic.com, or phone 1-800-998-8800.For small orders, phone 408-737-7600 ext. 3468.________

Página 2

MAX125/MAX126Reading a ConversionDigitized data from up to four channels are stored inmemory to be read out through the parallel interface.After recei

Página 3

1ppm/°C (max) temperature drift. Connect an externalreference at REFIN as shown in Figure 7. The minimumimpedance is 7kΩ for DC currents in both norma

Página 4

MAX125/MAX126The circuit of Figure 10 shows a typical vector motor-control application using all available inputs of theMAX125/MAX126. CH1A and CH2A a

Página 5

MAX125/MAX1262x4-Channel, Simultaneous-Sampling14-Bit DAS______________________________________________________________________________________ 13Figu

Página 6

MAX125/MAX1262x4-Channel, Simultaneous-Sampling14-Bit DAS14 ______________________________________________________________________________________3635

Página 7

MAX125/MAX1262x4-Channel, Simultaneous-Sampling14-Bit DAS______________________________________________________________________________________ 15____

Página 8

MAX125/MAX1262x4-Channel, Simultaneous-Sampling14-Bit DASMaxim cannot assume responsibility for use of any circuitry other than circuitry entirely emb

Página 9

MAX125MAX125/MAX1262x4-Channel, Simultaneous-Sampling14-Bit DAS2 _____________________________________________________________________________________

Página 10

µAMAX125/MAX1262x4-Channel, Simultaneous-Sampling14-Bit DAS_______________________________________________________________________________________ 3EL

Página 11

MAX125/MAX1262x4-Channel, Simultaneous-Sampling14-Bit DAS4 _______________________________________________________________________________________COND

Página 12

MAX125/MAX1262x4-Channel, Simultaneous-Sampling14-Bit DAS_______________________________________________________________________________________ 5COND

Página 13

_______________Detailed DescriptionThe MAX125/MAX126 use a successive-approximationconversion technique and four simultaneous-samplingtrack/hold (T/H)

Página 14

MAX125/MAX1262x4-Channel, Simultaneous-Sampling14-Bit DAS_______________________________________________________________________________________ 7MUX2

Página 15

MAX125/MAX1262x4-Channel, Simultaneous-Sampling14-Bit DAS8 _______________________________________________________________________________________sign

Página 16

Between conversions, the buffer input is connected tochannel 1 of the selected track/hold bank. When achannel is not selected, switches S1, S2, and S3