MAX1363/MAX1364
4-Channel, 12-Bit System Monitors with Programmable
______________________________________________________________________________________ 17
HIGH CH1 CH0 12/11
11
00
00
HIGH HIGH
DATA
(MSB)
D8 D7 D6 D5 D4 D3 D2 D1 D0
1 0/1 0/1
0 = 10b
1 = 12b
110/1 0/1 ACK 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1
ACK/
NACK
START
CONDITION
START
ADDRESS
FROM THE MASTER
1, CH ADD, 10b/12b FLAG,
RESULT (4 MSBs)
RESULT (8 LSBs)
1 ACK ACK ACK STOP
R/W
t
ACQ
t
CONV
Figure 10. Example of Reading the Conversion Result—External Clock Mode
START
ADDRESS
FROM THE MASTER
MAX1363/MAX1364
KEEPS SCL LOW
RESULT (8 LSBs)
1, CH ADD, 10b/12b,
RESULT (4 MSBs)
1 ACK
ACK
ACK STOP
t
ACQ
t
CONV
6.8µs MAX
R/W
Figure 11. Example of a Single Conversion Using the Internal Clock, SCAN = 1,1
START
MAX1363/MAX1364
KEEPS SCL LOW
ADDRESS
FROM THE MASTER
1 ACK
ACKACK
t
ACQ
t
CONV
t
ACQ
t
CONV
CONVERSION 1
6.8µs MAX
CONVERSION 2
MAX1363/MAX1364
KEEPS SCL LOW
1, CH ADD, 10b/12b,
RESULT (4 MSBs)
RESULT 1
(8 LSBs)
STOPACK
ACK
1, CH ADD, 10b/12b,
RESULT (4 MSBs)
RESULT N
(8 LSBs)
t
ACQ
t
CONV
CONVERSION N
R/W
Figure 12. Example of Scan-Mode Conversions Using the Internal Clock, SCAN = 0,0 and 0,1