Pin Description (continued)
PIN NAME FUNCTION
11
CLKTYP
Clock Type Definition Input. Connect CLKTYP to GND to define the single-ended clock input. Connect
CLKTYP to OV
DD
or V
DD
to define the differential clock input.
12–15,
36
V
DD
Analog Power Input. Connect V
DD
to a 3.0V to 3.6V power supply. Bypass V
DD
to GND with a parallel
capacitor combination of 2.2µF and 0.1µF. Connect all V
DD
pins to the same potential.
17, 34 OV
DD
Output Driver Power Input. Connect OV
DD
to a 1.7V to V
DD
power supply. Bypass OV
DD
to GND with a
parallel capacitor combination of 2.2µF and 0.1µF.
18 DOR
Data Out-of-Range Indicator. The DOR digital output indicates when the analog input voltage is out of
range. When DOR is high, the analog input is beyond its full-scale range. When DOR is low, the analog
input is within its full-scale range.
19 D11 CMOS Digital Output, Bit 11 (MSB)
20 D10 CMOS Digital Output, Bit 10
21 D9 CMOS Digital Output, Bit 9
22 D8 CMOS Digital Output, Bit 8
23 D7 CMOS Digital Output, Bit 7
24 D6 CMOS Digital Output, Bit 6
25 D5 CMOS Digital Output, Bit 5
26 D4 CMOS Digital Output, Bit 4
27 D3 CMOS Digital Output, Bit 3
28 D2 CMOS Digital Output, Bit 2
29 D1 CMOS Digital Output, Bit 1
30 D0 CMOS Digital Output, Bit 0 (LSB)
31, 32 I.C. Internally Connected. Leave I.C. unconnected.
33 DAV
Data Valid Output. The DAV is a single-ended version of the input clock that is compensated to correct
for any input clock duty-cycle variations. DAV is typically used to latch the MAX1211 output data into an
external back-end digital circuit.
37 PD Power-Down Input. Force PD high for power-down mode. Force PD low for normal operation.
38
REFOUT
Internal Reference Voltage Output. For internal reference operation, connect REFOUT directly to REFIN
or use a resistive divider from REFOUT to set the voltage at REFIN. Bypass REFOUT to GND with a
0.1µF capacitor.
39 REFIN Reference Input. V
REFIN
= 2 x (V
REFP
- V
REFN
). Bypass REFIN to GND with a 0.1µF capacitor.
40 G/T
Output Format Select Input. Connect G/T to GND for the two’s complement digital output format. Connect
G/T to OV
DD
or V
DD
for the Gray code digital output format.
—EP
Exposed Paddle. EP is internally connected to GND. Externally connect EP to GND to achieve specified