Rainbow-electronics LM93 Manual do Utilizador Página 36

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 92
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 35
16.0 Registers (Continued)
Lock Register Name Address Default Description
LIMIT REGISTERS
Zone 2 (CPU2) High Temp 7Bh 80h High limit for external thermal diode temperature channel 2
(D2) measurement
Zone 3 (Internal) Low Temp 7Ch 80h Low limit for local temperature measurement
Zone 3 (Internal) High Temp 7Dh 80h High limit for local temperature measurement
Zone 4 (External Digital) Low Temp 7Eh 80h Low limit for external digital temperature sensor
Zone 4 (External Digital) High Temp 7Fh 80h High limit for external digital temperature sensor
x Fan Boost Temp Zone 1 80h 3Ch Zone 1 (CPU1) fan boost temperature
x Fan Boost Temp Zone 2 81h 3Ch Zone 2 (CPU2) fan boost temperature
x Fan Boost Temp Zone 3 82h 23h Zone 3 (Internal) fan boost temperature
x Fan Boost Temp Zone 4 83h 23h Zone 4 (External Digital) fan boost temperature
Reserved 84h-8Fh N/D
AD_IN1 Low Limit 90h 00h Low limit for analog input 1 measurement
AD_IN1 High Limit 91h FFh High limit for analog input 1 measurement
AD_IN2 Low Limit 92h 00h Low limit for analog input 2 measurement
AD_IN2 High Limit 93h FFh High limit for analog input 2 measurement
AD_IN3 Low Limit 94h 00h Low limit for analog input 3 measurement
AD_IN3 High Limit 95h FFh High limit for analog input 3 measurement
AD_IN4 Low Limit 96h 00h Low limit for analog input 4 measurement
AD_IN4 High Limit 97h FFh High limit for analog input 4 measurement
AD_IN5 Low Limit 98h 00h Low limit for analog input 5 measurement
AD_IN5 High Limit 99h FFh High limit for analog input 5 measurement
AD_IN6 Low Limit 9Ah 00h Low limit for analog input 6 measurement
AD_IN6 High Limit 9Bh FFh High limit for analog input 6 measurement
AD_IN7 Low Limit 9Ch 00h Low limit for analog input 7 measurement
AD_IN7 High Limit 9Dh FFh High limit for analog input 7 measurement
AD_IN8 Low Limit 9Eh 00h Low limit for analog input 8 measurement
AD_IN8 High Limit 9Fh FFh High limit for analog input 8 measurement
AD_IN9 Low Limit A0h 00h Low limit for analog input 9 measurement
AD_IN9 High Limit A1h FFh High limit for analog input 9 measurement
AD_IN10 Low Limit A2h 00h Low limit for analog input 10 measurement
AD_IN10 High Limit A3h FFh High limit for analog input 10 measurement
AD_IN11 Low Limit A4h 00h Low limit for analog input 11 measurement
AD_IN11 High Limit A5h FFh High limit for analog input 11 measurement
AD_IN12 Low Limit A6h 00h Low limit for analog input 12 measurement
AD_IN12 High Limit A7h FFh High limit for analog input 12 measurement
AD_IN13 Low Limit A8h 00h Low limit for analog input 13 measurement
AD_IN13 High Limit A9h FFh High limit for analog input 13 measurement
AD_IN14 Low Limit AAh 00h Low limit for analog input 14 measurement
AD_IN14 High Limit ABh FFh High limit for analog input 14 measurement
AD_IN15 Low Limit ACh 00h Low limit for analog input 15 measurement
AD_IN15 High Limit ADh FFh High limit for analog input 15 measurement
AD_IN16 Low Limit AEh 00h Low limit for analog input 16 measurement
AD_IN16 High Limit AFh FFh High limit for analog input 16 measurement
P1_PROCHOT User Limit
B0h FFh User settable limit for P1_PROCHOT
LM93
www.national.com 36