Figure 7. 3-WIRE COMMUNICATION
a) Start Temperature Conversion
b) Write to the T
H
/T
L
Registers
c) Write to the Configuration Register
d) Read from the Temperature Register
e) Read from the Configuration Register
CLK
101
0
Start Convert T [51h] Command
DQ
R
S
T
01
0
0
Configuration Reg. Data from Master
CLK
D
2
D
1
D
0
0
0
0
000
Write Config [0Ch] Command
DQ
R
S
T
D
3
D
4
D
5
D
6
D
7
1 1
CLK
D
2
D
1
D
0
00
0
0
DQ
× × ×
R
S
T
× × ×
D
3
D
4
D
5
D
6
D
7
D
8
00
D
9
D
10
D
11
C
7
C
6
Write TH [01h] or TL [02h] Command
T
H
or T
L
Data from Master
Configuration Reg. Data from DS1626/DS1726
CLK
D
2
D
1
D
0
010100
Read Config [ACh] Command
DQ
R
S
T
D
3
D
4
D
5
D
6
D
7
1 1
Temperature Data from DS1626/DS1726
CLK
D
2
D
1
D
0
01
0
1
Read Temperature [AAh] Command
DQ
× × ×
R
S
T
× × ×
D
3
D
4
D
5
D
6
D
7
D
8
0
101
D
9
D
10
D
1
1
000
× × ×