PMBus 6-Channel Power-Supply Manager
MAX34440
39
Table 24. MFR_NV_FAULT_LOG (continued)
Note: LOG_VALID is set to DDh if the fault log contains valid data.
BYTE PARAMETER BYTE PARAMETER
42 MFR_VOUT_PEAK Page 5 170 READ_VOUT Index = 6, Page 5
44 MFR_IOUT_PEAK Page 0 172 READ_VOUT Index = 7, Page 0
46 MFR_IOUT_PEAK Page 1 174 READ_VOUT Index = 7, Page 1
48 MFR_IOUT_PEAK Page 2 176 READ_VOUT Index = 7, Page 2
50 MFR_IOUT_PEAK Page 3 178 READ_VOUT Index = 7, Page 3
52 MFR_IOUT_PEAK Page 4 180 READ_VOUT Index = 7, Page 4
54 MFR_IOUT_PEAK Page 5 182 READ_VOUT Index = 7, Page 5
56 MFR_TEMPERATURE_PEAK Page 6 184 RESERVED (0000h)
58 MFR_TEMPERATURE_PEAK Page 7 186 CURRENT_INDEX/00h
60 MFR_TEMPERATURE_PEAK Page 8 188 READ_IOUT Index = 0, Page 0
62 MFR_TEMPERATURE_PEAK Page 9 190 READ_IOUT Index = 0, Page 1
64 MFR_TEMPERATURE_PEAK Page 10 192 READ_IOUT Index = 0, Page 2
66 MFR_TEMPERATURE_PEAK Page 11 194 READ_IOUT Index = 0, Page 3
68 MFR_TEMPERATURE_PEAK Page 12 196 READ_IOUT Index = 0, Page 4
70 MFR_TEMPERATURE_PEAK Page 13 198 READ_IOUT Index = 0, Page 5
72 MFR_VOUT_MIN Page 0 200 READ_IOUT Index = 1, Page 0
74 MFR_VOUT_MIN Page 1 202 READ_IOUT Index = 1, Page 1
76 MFR_VOUT_MIN Page 2 204 READ_IOUT Index = 1, Page 2
78 MFR_VOUT_MIN Page 3 206 READ_IOUT Index = 1, Page 3
80 MFR_VOUT_MIN Page 4 208 READ_IOUT Index = 1, Page 4
82 MFR_VOUT_MIN Page 5 210 READ_IOUT Index = 1, Page 5
84 RESERVED (0000h) 212 READ_IOUT Index = 2, Page 0
86 VOLTAGE_INDEX/00h 214 READ_IOUT Index = 2, Page 1
88 READ_VOUT Index = 0, Page 0 216 READ_IOUT Index = 2, Page 2
90 READ_VOUT Index = 0, Page 1 218 READ_IOUT Index = 2, Page 3
92 READ_VOUT Index = 0, Page 2 220 READ_IOUT Index = 2, Page 4
94 READ_VOUT Index = 0, Page 3 222 READ_IOUT Index = 2, Page 5
96 READ_VOUT Index = 0, Page 4 224 READ_IOUT Index = 3, Page 0
98 READ_VOUT Index = 0, Page 5 226 READ_IOUT Index = 3, Page 1
100 READ_VOUT Index = 1, Page 0 228 READ_IOUT Index = 3, Page 2
102 READ_VOUT Index = 1, Page 1 230 READ_IOUT Index = 3, Page 3
104 READ_VOUT Index = 1, Page 2 232 READ_IOUT Index = 3, Page 4
106 READ_VOUT Index = 1, Page 3 234 READ_IOUT Index = 3, Page 5
108 READ_VOUT Index = 1, Page 4 236 RESERVED (0000h)
110 READ_VOUT Index = 1, Page 5 238 READ_TEMPERATURE_1 Page 6
112 READ_VOUT Index = 2, Page 0 240 READ_TEMPERATURE_1 Page 7
114 READ_VOUT Index = 2, Page 1 242 READ_TEMPERATURE_1 Page 8
116 READ_VOUT Index = 2, Page 2 244 READ_TEMPERATURE_1 Page 9
118 READ_VOUT Index = 2, Page 3 246 READ_TEMPERATURE_1 Page 10
120 READ_VOUT Index = 2, Page 4 248 READ_TEMPERATURE_1 Page 11
122 READ_VOUT Index = 2, Page 5 250 READ_TEMPERATURE_1 Page 12
124 READ_VOUT Index = 3, Page 0 252 READ_TEMPERATURE_1 Page 13
126 READ_VOUT Index = 3, Page 1 254 LOG_VALID (see note)