Rainbow-electronics MAX16066 Manual do Utilizador Página 15

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 61
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 14
12-Channel/8-Channel, Flash-Configurable System
Managers with Nonvolatile Fault Registers
MAX16065/MAX16066
______________________________________________________________________________________ 15
Figure 3. Delay and Reset Timing
Table 5. MON_ and EN_OUT_ Assignment Registers
REGISTER
ADDRESS
FLASH
ADDRESS
BIT RANGE DESCRIPTION
7Eh 27Eh
[3:0] MON1
[7:4] MON2
7Fh 27Fh
[3:0] MON3
[7:4] MON4
80h 280h
[3:0] MON5
[7:4] MON6
81h 281h
[3:0] MON7
[7:4] MON8
82h 282h
[3:0] MON9
[7:4] MON10
83h 283h
[3:0] MON11
[7:4] MON12
SLOT 0
EN_OUT1
BOTH ARE
ASSIGNED
TO SLOT 1
MON4
EN_OUT2
MON3
MON5
RESET
EN
SLOT 1
t
FAULT
OV
UV
SLOT1-SLOT2
DELAY
SLOT1-SLOT2
DELAY
MON4 MUST
REACH UV
THRESHOLD BY THIS
TIME
UV/OV
MONITORING BEGINS
WHEN MON4
REACHES UV
THRESHOLD
SLOT 2
FINAL SLOT
(PRIMARY
SEQUENCE)
RESET
TIMEOUT
BOTH ARE
ASSIGNED
TO SLOT 2
Vista de página 14