Rainbow-electronics MAX6964 Manual do Utilizador Página 12

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 23
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 11
MAX6964
17-Output LED Driver/GPO
with Intensity Control
12 ______________________________________________________________________________________
Table 4. Configuration Register (continued)
REGISTER DATA
REGISTER
ADDRESS
CODE
(hex)
D7 D6 D5 D4 D3 D2 D1 D0
CONFIGURATION
R/W
0
BLINK
STATUS
OUTPUT
O16
0
GLOBAL
INTENSITY
BLINK FLIP
BLINK
ENABLE
Write device configuration
0
XX
Read back device configuration
1
0
BLINK O1
O0
0
GBE
Disable global intensity control—intensity
is set by registers 0x10–0x17 for ports O0
through O15 when configured as outputs,
and by D3–D0 of register 0x0E for output
XXXXX0 XX
Enable global intensity control—intensity
for all ports configured as outputs is set
by D3–D0 of register 0x0E
XXXXX1 XX
O16 output is low (blink is disabled)
XXX00XX0
O16 output is high impedance (blink is
disabled)
XXX10XX0
O 16 outp ut i s l ow d ur i ng b l i nk p hase 0
XXX00XX1
O16 output is high impedance during
blink phase 0
XXX10XX1
O 16 outp ut i s l ow d ur i ng b l i nk p hase 1
XX0 X 0 XX1
O16 output is high impedance during
blink phase 1
XX1 X 0 XX1
Read back BLINK input pin status;
input is low
1
X 0 XXXXXX
Read back BLINK input pin status;
input is high
1
0x0F
X 1 XXXXXX
Table 5. Blink Controls
BLINK ENABLE
FLAG
E
BLINK FLIP
FLAG
B
BLINK INPUT
PIN
BLINK FLIP FLAG
EXOR
BLINK INPUT PIN
BLINK
FUNCTION
OUTPUT REGISTERS
USED
0XXXDisabled Blink phase 0
00 0 Blink phase 0
01 1 Blink phase 1
10 1 Blink phase 1
1
11 0
Enabled
Blink phase 0
X = Don’t care.
X = Don’t care.