4
4234F–SCR–10/05
AT83C24
SDA VCC
3 kV
I/O
open-
drain
Microcontroller Interface Function
TWI serial data
SCL VCC
3 kV
I/O
open-
drain
Microcontroller Interface Function
TWI serial clock
I/O EVCC
3 kV
I/O
Microcontroller Interface Function
Copy of CIO pin and high level reference for EVCC.
An external pull up to EVCC is needed on IO pin.
I/O is the reference level for EVCC if EVCC is connected to a capacitor.
This feature is unused if EVCC is connected to VCC.
C4 EVCC
3 kV I/O
(pull-up)
Microcontroller Interface Function
Copy of Card CC4.
C8 EVCC
3 kV I/O
(pull-up)
Microcontroller Interface Function
Copy of Card CC8.
CLK EVCC
3 kV
I
Microcontroller Interface Function
Master Clock
CIO CVCC 8 kV+
I/O
(pull-up)
Smart card interface function
Card I/O
CC4 CVCC 8 kV+
I/O
(pull-up)
Smart card interface function
Card C4
CC8 CVCC 8 kV+
I/O
(pull-up)
Smart card interface function
Card C8
CPRES VCC 8 kV+
I
(pull-up)
Smart card interface function
Card presence
An internal Pull-up to VCC can be activated in the pad if necessary using PULLUP bit
(CONFIG1 register).
CCLK CVCC 8 kV+ O
Smart card interface function
Card clock
CRST CVCC 8 kV+ O
Smart card interface function
Card reset
CMDVCC EVCC
3 kV+
I
(pull-up)
Microcontroller Interface Function:
Activation/Shutdown of the smart card Interface.
VCC 3 kV+ PWR
Supply Voltage
V
CC
is used to power the internal voltage regulators and I/O buffers.
LI 3 kV+ PWR
DC/DC Input
LI must be tied to VCC pin through an external coil (typically 4.7 μH) and provides the
current for the charge pump of the DC/DC converter.
It may be directly connected to VCC if the step-up converter is not used (see STEPREG
bit in CONFIG4 register and see minimum VCC values in
Table 20 (class A) and
Table 21 (class B)).
Table 1. Ports Description (Continued)
Pad Name Pad Internal
Power Supply
ESD
Limits
Pad
Type Description
Comentários a estes Manuais