Power-Management ICs for
ICERA E400/E450 Platform
MAX8982A/MAX8982X
16
OUT8 (LDO8) ELECTRICAL CHARACTERISTICS
(MAX8982A only, V
IN4
= V
IN1_
= +5.0V, C
IN4
= 1.0FF, C
REFBP
= 0.1FF, C
OUT8
= 1FF, T
A
= -40NC to +85NC, unless otherwise noted.
Typical values are at T
A
= +25NC.) (Note 3)
OUT9 (LDO9) ELECTRICAL CHARACTERISTICS
(MAX8982A/MAX8982X: V
IN3
= V
BUCK2
= 1.8V, C
IN3
= 2.2FF, C
REFBP
= 0.1FF, C
OUT9
= 2.2FF, T
A
= -40NC to +85NC, unless other-
wise noted. Typical values are at T
A
= +25NC.) (Note 3)
PARAMETER CONDITION MIN TYP MAX UNITS
Input Operating Range Guaranteed by output voltage accuracy 3.0 5.5 V
Overvoltage Lockout
(Shutdown LDO8 Output)
V
IN4
rising, V
IN1_
= V
IN4
5.75 5.93 V
Overvoltage Hysteresis 250 mV
Default Output Voltage I
LOAD
= 50mA 2.91 3.00 3.09 V
Maximum Output Current 150 mA
Current Limit (Note 4) V
OUT8
= 90% of its regulation 165 360 650 mA
Dropout Voltage (Note 4) 100mA, T
A
= +85NC 150 300 mV
Line Regulation 3.4V P V
IN4
P 5.5V, V
OUT8
= 3.1V, I
LOAD
= 100mA 2.2 mV
Load Regulation 50FA < I
LOAD
< 150mA 25 mV
Power-Supply Rejection
DV
OUT
/DV
IN
f = 10Hz to 10kHz, I
LOAD
= 30mA 60 dB
Output Noise Voltage (RMS) 100Hz to 100kHz, I
LOAD
= 30mA 45 FV
RMS
Programmable Output Voltage I
LOAD
= 50mA
3.00
V
3.10
3.20
3.30
Startup Time from Shutdown
(Note 4)
I
LOAD
= 150mA 100 Fs
Startup Transient Overshoot
(Note 4)
I
LOAD
= 150mA 50 mV
Shutdown Output Impedance
(Active Discharge Resistance)
I
2
C programmable, default off 100
I
PARAMETER CONDITION MIN TYP MAX UNITS
Default Output Voltage ±I
LOAD
= 10mA, V
IN3
=
1.8V 0.873 0.900 0.927 V
Maximum Output Current 50 mA
Current Limit (Note 4) V
OUT9
= 90% of its regulation 55 120 220 mA
Load Regulation 50FA < I
LOAD
< 50mA 25 mV
Power-Supply Rejection
DV
OUT
/DV
IN
f = 10Hz to 10kHz, I
LOAD
= 10mA 60 dB
Output Noise Voltage 100Hz to 100kHz, I
LOAD
= 10mA 45 FV
RMS
Programmable Output Voltage I
LOAD
= 10mA
0.80
V
0.90
1.00
1.10
1.20
Startup Time from Shutdown
(Note 4)
I
LOAD
= 50mA 100 Fs