MAX6655/MAX6656
Dual Remote/Local Temperature Sensors and
Four-Channel Voltage Monitors
_______________________________________________________________________________________ 3
ELECTRICAL CHARACTERISTICS (continued)
(V
CC
= +3.0V to +3.6V for MAX6656, V
CC
= +4.5V to +5.5V for MAX6655, T
A
= -55°C to +125°C, unless otherwise noted. Typical values
are at V
CC
= +3.3V for MAX6656, V
CC
= +5.0V for MAX6655, T
A
= +25°C.)
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
High level 80 100 140
Remote Junction Current
(DXP, DXN)
Low level 8 10 14
µA
SMBus INTERFACE (SMBCLK, SMBDATA, STBY)
Logic Input Low Voltage V
IL
V
CC
= +3.0V to +5.5V 0.8 V
V
CC
= +3.0V 2.1
Logic Input High Voltage V
IH
V
CC
= +5.5V 2.6
V
Input Leakage Current I
LEAK
V
IN
= GND or V
CC
±1µA
Output Low Sink Current I
OL
V
OL
= +0.6V 6 mA
Input Capacitance C
IN
5pF
SMBus Timeout SMBCLK or SMBDATA time low for reset 30 35 60 ms
ALERT, OVERT
Output Low Sink Current V
OL
= +0.6V 6 mA
Output High Leakage Current V
OH
= +5.5V 1 µA
SMBus TIMING
Serial Clock Frequency f
SCL
400 kHz
Bus Free Time Between STOP
and START Condition
t
BUF
4.7 µs
START Condition Setup Time 4.7 µs
Repeat START Condition Setup
Time
t
SU:STA
90% to 90% 50 ns
START Condition Hold Time t
HD:STA
10% of SMBDATA to 90% of SMBCLK 4 µs
STOP Condition Setup Time t
SU:STO
90% of SMBCLK to 10% of SMBDATA 4 µs
Clock Low Period t
LOW
10% to 10% 4.7 µs
Clock High Period t
HIGH
90% to 90% 4 µs
Data Setup Time t
SU:DAT
90% of SMBDATA to 10% of SMBCLK 250 ns
Data Hold Time t
HD:DAT
(Note 1) 0 µs
Receive SMBCLK/SMBDATA
Rise Time
t
R
1µs
Receive SMBCLK/SMBDATA
Fall Time
t
F
300 ns
Pulse Width of Spike
Suppressed
t
SP
050ns