MAX6642
±1°C, SMBus-Compatible Remote/Local
Temperature Sensor with Overtemperature Alarm
_______________________________________________________________________________________ 3
Note 1: All parameters tested at T
A
= +25°C. Specifications over temperature are guaranteed by design.
Note 2: Timing specifications guaranteed by design.
Note 3: The serial interface resets when SCLK is low for more than t
TIMEOUT
.
Note 4: A transition must internally provide at least a hold time to bridge the undefined region (300ns max) of SCLK’s falling edge.
ELECTRICAL CHARACTERISTICS (continued)
(V
CC
= +3.0V to +5.5V, T
A
= -40°C to +125°C, unless otherwise specified. Typical values are at V
CC
= +3.3V and T
A
= +25°C.) (Note 1)
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
SMBus-COMPATIBLE INTERFACE (SCLK and SDA)
Logic Input Low Voltage V
IL
0.8 V
Logic Input High Voltage V
IH
V
CC
= 3.0V 2.2 V
Input Leakage Current I
LEAK
V
IN
= GND or 5.5V -1 +1 µA
Output Low Sink Current I
OL
V
OL
= 0.6V 6 mA
Input Capacitance C
IN
5pF
SMBus TIMING (Note 2)
Serial Clock Frequency f
SCLK
(Note 3) 100 kHz
Bus Free Time Between STOP
and START Condition
t
BUF
4.7 µs
START Condition Setup Time 4.7 µs
Repeat START Condition Setup
Time
t
SU:STA
90% to 90% 50 ns
START Condition Hold Time t
HD:STA
10% of SDA to 90% of SCLK 4 µs
STOP Condition Setup Time t
SU:STO
90% of SCLK to 90% of SDA 4 µs
Clock Low Period t
LOW
10% to 10% 4.7 µs
Clock High Period t
HIGH
90% to 90% 4 µs
Data Setup Time t
HD:DAT
(Note 4) 250 µs
Receive SCLK/SDA Rise Time t
R
1µs
Receive SCLK/SDA Fall Time t
F
300 ns
Pulse Width of Spike Suppressed t
SP
050ns
SMBus Timeout t
TIMEOUT
SDA low period for interface reset 20 28 40 ms