cases, the alert is cleared even if the fault condition
exists, but the ALERT output reasserts at the end of the
next conversion. The bits indicating the fault for the
OVERT interrupt output clear only on reading the status 2
register even if the fault conditions still exist. Reading the
status 2 register does not clear the OVERT interrupt out-
put. To eliminate the fault condition, either the measured
temperature must drop below the temperature threshold
minus the hysteresis value (4°C), or the trip temperature
must be set at least 4°C above the current temperature.
MAX6622
5-Channel Precision Temperature Monitor
______________________________________________________________________________________ 11
REGISTER
ADDRESS
(hex)
POR STATE
(hex)
READ/
WRITE
DESCRIPTION
Local 07 00 R Read local temperature register
Remote 1 01 00 R Read channel 1 remote temperature register
Remote 2 02 00 R Read channel 2 remote temperature register
Remote 3 03 00 R Read channel 3 remote temperature register
Remote 4 04 00 R Read channel 4 remote temperature register
Configuration 1 41 00 R/W Read/write configuration register 1
Configuration 2 42 00 R/W Read/write configuration register 2
Configuration 3 43 00 R/W Read/write configuration register 3
Status1 44 00 R Read status register 1
Status2 45 00 R Read status register 2
Status3 46 00 R Read status register 3
Local ALERT High Limit 17 5A R/W Read/write local alert high-temperature threshold limit register
Remote 1 ALERT High Limit 11 6E R/W
Read/write channel 1 remote-diode alert high-temperature
threshold limit register
Remote 2 ALERT High Limit 12 7F R/W
Read/write channel 2 remote-diode alert high-temperature
threshold limit register
Remote 3 ALERT High Limit 13 64 R/W
Read/write channel 3 remote-diode alert high-temperature
threshold limit register
Remote 4 ALERT High Limit 14 64 R/W
Read/write channel 4 remote-diode alert high-temperature
threshold limit register
Remote 1 OVERT High Limit 21 6E R/W
Read/write channel 1 remote-diode overtemperature threshold
limit register
Remote 4 OVERT High Limit 24 7F R/W
Read/write channel 4 remote-diode overtemperature threshold
limit register
Remote 1 Extended
Temperature
09 00 R Read channel 1 remote-diode extended temperature register
Manufacturer ID 0A 4D R Read manufacturer ID
Table 3. Command Byte Register Bit Assignment