MAX5957/MAX5958
Triple PCI Express, Hot-Plug Controllers
______________________________________________________________________________________ 19
ENABLE CHARGE ON
INTERNAL AUXILIARY
MOSFET DRIVING 3.3AUXO_.
START COUNTING t
SU
FAULT ON 12V
OR 3.3V OUTPUTS
RESET t
FAULT
COUNTER
FAULT
STILL PRESENT?
Y
Y
Y
Y
Y
SHUT DOWN
12V AND 3.3V OUTPUTS.
ASSERT FAULT_
STAY WAITING FOR
t
RESTART
t
FAULT
ELAPSED?
N
N
N
N
3.3VAUXIN IS OK,
AUXON_ IS HIGH,
PRES_DET IS LOW
RESET FAULT_
START COUNTING
t
FAULT
Y
N
N
N
ARE ALL
MAIN OUTPUTS OK?
NO FAULT
DETECTED
LATCH-OFF
OPTION?
N
ON_ TOGGLED
HIGH LOW HIGH
MAIN INPUTS ARE
OK, ON_ IS HIGH
Y
Y
N
ENABLE CHARGE
ON 3.3G_ AND 12G_.
START
COUNTING t
SU
t
SU
ELAPSED?
Y
START PGOOD
THRESHOLD
MONITORING
START COUNTING
t
FAULT
ALL PGOOD
THRESHOLDS
REACHED?
N
N
N
N
Y
Y
Y
Y
ASSERT PWRGD_
AFTER t
POR_HL
DELAY
RESET PWRGD_
POWER ON
AUXILIARY OUTPUT.
FAULT_ AND PWRGD_ ARE
HIGH IMPEDANCE
SHUT DOWN ALL OUTPUTS.
ASSERT FAULT_.
STAY WAITING
FOR t
RESTART
RESET FAULT_
ON_ AND
AUXON_ TOGGLED
HIGH LOW
HIGH
t
SU
ELAPSED?
AUX OUTPUT OK?
NO FAULT DETECTED
FAULT ON 3.3AUXO_?
N
N
t
FAULT
ELAPSED?
Y
FAULT
STILL PRESENT?
N
Y
Y
LATCH-OFF
OPTION?
RESET t
FAULT
COUNTER
Figure 6. Fault Management Flowchart