MAX5094A/B/C/D/MAX5095A/B/C
Current-Mode Control Loop
The advantages of current-mode control over voltage-
mode control are twofold. First, there is the feed-forward
characteristic brought on by the controller’s ability to
adjust for variations in the input voltage on a cycle-by-
cycle basis. Secondly, the stability requirements of the
current-mode controller are reduced to that of a single-
pole system unlike the double pole in the voltage-mode
control scheme.
The MAX5094/MAX5095 use a current-mode control loop
where the output of the error amplifier is compared to the
current-sense voltage (V
CS
). When the current-sense sig-
nal is lower than the inverting input of the CPWM com-
parator, the output of the comparator is low and the
switch is turned on at each clock pulse. When the cur-
rent-sense signal is higher than the inverting input of the
CPWM comparator, the output is high and the switch is
turned off.