MAX4885
Complete VGA 1:2 or 2:1 Multiplexer
8 _______________________________________________________________________________________
Timing Circuits/Timing Diagrams (continued)
MEASUREMENTS ARE STANDARDIZED AGAINST SHORTS AT IC TERMINALS.
OFF-ISOLATION IS MEASURED BETWEEN R0 AND R1 OR R2 ON EACH SWITCH.
ON-LOSS IS MEASURED BETWEEN R0 AND R1 OR R2 ON EACH SWITCH.
CROSSTALK IS MEASURED FROM ONE CHANNEL TO THE OTHER CHANNEL.
SIGNAL DIRECTION THROUGH SWITCH IS REVERSED; WORST VALUES ARE RECORDED.
+5V
V
OUT
V+
SEL
V
IN
MAX4885
OFF-ISOLATION = 20log ✕
V
OUT
V
IN
ON-LOSS = 20log ✕
V
OUT
V
IN
CROSSTALK = 20log ✕
V
OUT
V
IN
NETWORK
ANALYZER
50Ω
50Ω 50Ω
50Ω
MEAS REF
10nF
0V OR V+
50Ω
GND
R0, G0, B0
R2, G2, B2
R1, G1, B1
Figure 4. On-Loss, Off-Isolation, and Crosstalk
Pin Description
PIN NAME FUNCTION
1 QP
Charge-Pump Enable, Active Low. Drive QP low for normal operation. Drive QP high to disable the
internal charge pump.
2R0RGB Analog I/O
3G0RGB Analog I/O
4B0RGB Analog I/O
5H0Horizontal Sync I/O
6V0Vertical Sync I/O
7 DDCA0 DDC I/O
8 DDCB0 DDC I/O
9 EN
Enable Input, Active Low. Drive EN low for normal operation. Drive EN high to disable the device. All
I/Os are high-impedance and charge pump is off when the device is disabled.
10 V
CL
DDC Clamp Voltage. Open-drain DDCA_ and DDCB_ outputs are clamped to one diode-drop below
V
CL
. +2.7V < V
CL
< V+. Connect V
CL
to +3.3V for voltage clamping, or connect to V+ to disable
clamping. Bypass V
CL
to GND with a 0.1µF or larger ceramic capacitor.
V+ Supply Voltage. V+ = +5.0V ± 10%. Bypass each to GND with a 0.1µF or larger ceramic capacitor.
GND Ground
13 DDCA2 DDC I/O
14 DDCB2 DDC I/O
15 R2 RGB Analog I/O
16 G2 RGB Analog I/O
17 B2 RGB Analog I/O