Complete DDR2 and DDR3 Memory
Power-Management Solution
______________________________________________________________________________________ 21
Soft-shutdown begins after SHDN goes low, an output
undervoltage fault occurs, or a thermal fault occurs. A
fault on the SMPS (UV fault for more than 200μs (typ)),
or fault on the VTT output that persists for more than
5ms (typ), triggers shutdown of the whole IC. During
soft-shutdown, the output is ramped down to 0V in
2.8ms, reducing negative inductor currents that can
cause negative voltages on the output. At the end of
soft-shutdown, DL is driven low.
When OVP is enabled (OVP = V
CC
), the internal 16Ω
discharging MOSFETs on CSL and VTT are enabled
until startup is triggered again by a rising edge of
SHDN. When OVP is disabled (OVP = AGND), the CSL
and VTT internal 16Ω discharging MOSFETs are not
enabled in shutdown.
Output Fault Protection
The MAX17000 provides overvoltage/undervoltage fault
protections for the PWM output. Drive OVP to enable
and disable fault protection as shown in Table 4.
STDBY
INT_REF
SMPS OUTPUT
REFOK
SMPS_RUNOK
PGOOD1
160μs
SHDN
VTT OUTPUT
VTTR OUTPUT
DL
VTT CURRENT LIMIT
PGOOD2
1.4ms
2.8ms
VTT 16Ω FET
SKIP FPWM
CSL 16Ω FET
25mV
Figure 6. MAX17000 Startup/Shutdown Timing when OVP Is Enabled