DC ELECTRICAL CHARACTERISTICS:
DIGITAL THERMOMETER (-55°C to +125°C; 2.7V ≤ V
DD
≤ 5.5V)
PARAMETER SYMBOL CONDITION MIN TYP MAX UNITS NOTES
DS1629 Thermometer
Error
T
ERR
-10°C to
+85°C
2.7V ≤ V
DD
≤ 5.5V
±2.0 °C 6
Resolution 0.03 0.5 °C 7
Conversion Time t
CONVT
400 1000 ms
AC ELECTRICAL CHARACTERISTICS:
2-WIRE INTERFACE (-55°C to +125°C; 2.2V ≤ V
DD
≤ 5.5V)
PARAMETER SYMBOL CONDITION MIN TYP MAX UNITS NOTES
SCL Clock Period t
1
2.5 µs
Data In Setup Time to
SCL High
t
2
100 ns
Data Out Stable after
SCL Low
t
3
0 ns
SDA Low Setup
Time to SCL
Low (START)
t
4
100 ns
SDA High Hold
Time After SCL
High (STOP)
t
5
100 ns
Capacitance Load for
each Bus Line
C
b
400 pF 8
Input Capacitance C
I
5 pF
Crystal Capacitance C
C
12.5 pF 9
NOTES:
1. All voltages are referenced to ground, unless otherwise noted.
2. Logic 0 voltage specified at a sink current of 4 mA at V
DD
=5.0V and 1.5 mA at V
DD
=2.2V.
3. I/O pins of fast mode devices must not obstruct the SDA and SCL lines if V
DD
is switched off.
4. Standby current specified with temperature conversions and clock oscillator/buffer shut down,
ALRM pin open, and SDA, SCL = V
DD
, 0°C to +70°C.
5. I
DDX
specified with ALRM pin open, and 0°C to +70°C.
6. See typical accuracy curve for specification limits outside the temperature range indicated.
Thermometer error is specified for 2.7V ≤ V
DD
≤ 5.5V. Accuracy will degrade approximately
0.5°C if ALRM is sinking the maximum current.
7. Thermometer resolution (in °C) = 1/COUNT_PER_C(T). The calibration algorithm is such that
COUNT_PER_C and thus resolution varies over temperature (but is constant at a given
temperature for a given device) and from device to device.