Rainbow-electronics MAX4995 Manual do Utilizador Página 3

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 12
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 2
MAX4995A/AF/AL/MAX4995B/MAX4995C
50mA to 600mA Programmable
Current-Limit Switches
_______________________________________________________________________________________ 3
Note 3: I
LIM
is forward current limit.
Note 4: Turn-on time and turn-off time are defined as the difference in the time between when the output crosses 10% and 90%
of the final output voltage.
Note 5: Blanking time and retry time are generated by the same oscillator. Therefore, the ratio of
is a constant value of 32. See Figures 2 and 3.
t
t
RETRY
BLANK
ELECTRICAL CHARACTERISTICS (continued)
(V
IN
= +1.7V to +5.5V, R
SETI
= 94.3kΩ, C
IN
= 1µF, and T
A
= T
J
= -40°C to +125°C, unless otherwise noted. Typical values are at V
IN
= +3.3V,
T
A
= +25°C.)
PARAMETER
SYMBOL
CONDITIONS
MIN TYP MAX
UNITS
DYNAMIC
Turn-On Time t
SS
V
IN
= 3.3V, C
OUT
= 1µF, R
L
= 20Ω, Figure 1,
(Note 4)
120
µs
Turn-Off Time t
OFF
S w i tch fr om on to off, V
I N
= 3.3V , C
OU T
= F,
R
L
= 20Ω, Figure 1 (Note 4)
120
µs
MAX4995A/AL/B/C
5
Current-Limit Reaction Time t
LIM
V
IN
= 3.3V, R
SETI
=
578kΩ, output high
and then short-circuit
applied
MAX4995AF 1.5
µs
Blanking Time
t
BLANK
(Note 5) 10
16.3 22.6
ms
Retry Time
t
RETRY
M AX 4995A/M AX 4995AF/M AX 4995AL ( N ote 5) 320 723.2
ms
THERMAL PROTECTION
Thermal Shutdown
+150
°C
Thermal-Shutdown Hysteresis 15 °C
t
SS
10%
90%
10%
90%
t
OFF
V
OUT
Figure 1. Timing Diagram for Measuring Turn-On Time (t
SS
) and Turn-Off Time (t
OFF
).
Vista de página 2