Rainbow-electronics GM862-QUAD-PY Manual do Utilizador Página 61

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 434
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 60
AT Commands Reference Guide
80000ST10025a Rev. 5 - 09/07/08
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 61 of 434
S2 - Escape Character SELINT 2
ATS2=[<char>]
Set command sets the ASCII character to be used as escape character.
Parameter:
<char> - escape character decimal ASCII
0..255 - factory default value is 43 (+).
Note: the escape sequence consists of three escape characters preceded
and followed by n ms of idle (see S12 to set n).
ATS2?
Read command returns the current value of S2 parameter.
Note: the format of the numbers in output is always 3 digits, left-filled with 0s
3.5.3.7.4 Command Line Termination Character - S3
S3 - Command Line Termination Character SELINT 0 / 1
ATS3[=<char>]
Set command sets the value of the character either recognized by the
device as command line terminator and generated by the device as part of
the header, trailer, and terminator for result codes and information text,
along with S4 parameter.
Parameter:
<char> - command line termination character (decimal ASCII)
0..127 - factory default value is 13 (ASCII CR)
Note: the “previous” value of S3 is used to determine the command line
termination character for entering the command line containing the S3
setting command. However the result code issued shall use the “new” value
of S3 (as set during the processing of the command line).
ATS3?
Read command returns the current value of S3 parameter.
ATS3=?
Test command returns the range for <char> without command echo and
parenthesis.
Note For either Read and Test command the format of the numbers in output is
always 3 digits, left-filled with 0s
Reference V25ter
S3 - Command Line Termination Character SELINT 2
ATS3=[<char>]
Set command sets the value of the character either recognized by the
device as command line terminator and generated by the device as part of
the header, trailer, and terminator for result codes and information text,
along with S4 parameter.
Parameter:
<char> - command line termination character (decimal ASCII)
0..127 - factory default value is 13 (ASCII <CR>)