Vista de página 272
Data Commands
Select Data Error Correcting Mode \N
©Restricted
Page: 83 / 156
This document is the sole and exclusive property of Wavecom. Not to be distributed or divulged without
prior written agreement.
WM_DEV_OAT_UGD_049 - 001 VOLUME 2 August 23, 2007
13.10 Select Data Error Correcting Mode \N
13.10.1 Description
This command controls the preferred error correcting mode for a data connection. It
can only be used for transparent data transmission.
13.10.2 Syntax
Action command
AT\N[<n>]
OK
Read command
AT\N?
<n>
OK
Test command
None
13.10.3 Parameters and Defined Values
<n>: error correction mode
0 disables error correcting mode (default value)
5 selects MNP error correcting mode
13.10.4 Parameter Storage
<n> is stored in EEPROM using the AT&W command. The default value can be
restored using AT&F.