MAX66100
ISO 15693-Compliant 64-Bit UID
______________________________________________________________________________________ 13
Detailed Command Descriptions
In the request data graphics of this section, the UID
field is shaded to indicate that the inclusion of the UID
depends on the address mode.
Get System Information
The Get System Information command is the only com-
mand beyond the network function level that the
MAX66100 supports. It allows the master to retrieve
technical information about the MAX66100. The IC ref-
erence code indicates the die revision in hexadecimal
format, such as A1h, A2h, B1h, etc.
CRC Generation
The ISO 15693 standard uses a 16-bit CRC, generated
according to the CRC-16-CCITT polynomial function:
X
16
+ X
12
+ X
5
+ 1 (see Figure 16). This CRC is used
for error detection in request and response data pack-
ets and is always communicated in the inverted form.
After all data bytes are shifted into the CRC generator,
the state of the 16 flip-flops is parallel-copied to a shift
register and shifted out for transmission with the LSb
first. For more details on this CRC, refer to ISO/IEC
15693-3, Annex C.