Rainbow-electronics MAX66020 Manual do Utilizador Página 15

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 25
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 14
MAX66020
IDLE
READY
POWER-OFF
WAITING FOR
SLOT-MARKER*
ACTIVEHALT
ANY OTHER COMMAND
IN FIELD
ANY OTHER
COMMAND
OR CASE
OUT OF FIELD
(FROM ANY STATE)
ANY OTHER COMMAND
RESPONSE LEGEND:
*WHEN ENTERING “WAITING FOR SLOT-MARKER,” EACH TAG SELECTS A RANDOM NUMBER R IN THE RANGE OF 1 TO “NUMBER OF SLOTS.”
DESELECT
(SPECIAL CASE OF A BLOCK TRANSMISSION
PROTOCOL FUNCTION)
ATQB RESPONSE1
A
a
b
s
A
B
S
S
BMS
1
1
1
4
3
2
ATTRIB RESPONSE2
HLTB RESPONSE3
DESELECT RESPONSE4
ANY OTHER
COMMAND
OR CASE
ANY OTHER
COMMAND OR CASE
ATTRIB WITH
MATCHING PUPI
HLTB WITH
MATCHING PUPI
EXECUTIVE BLOCK
TRANSMISSION
PROTOCOL FUNCTION
Figure 17. ISO/IEC 14443 Type B State Transitions Diagram
NAME DESCRIPTION RESULT
A (AFI MISMATCH) REQB/WUPB WITH NONMATCHING AFI
a WUPB WITH NONMATCHING AFI
RETURN TO IDLE
B (BYPASS SM) REQB/WUPB WITH MATCHING AFI AND [(N = 1) OR [R = 1)]
b WUPB WITH MATCHING AFI AND [(N = 1) OR [R = 1)]
TRANSITION DIRECTLY TO READY
S (SLOT-MARKER) REQB/WUPB WITH MATCHING AFI AND (N 1) AND (R 1)
s WUPB WITH MATCHING AFI AND (N 1) AND (R 1)
WAIT FOR MATCHING SLOT NUMBER
MS (MATCHING SLOT) SLOT-MARKER COMMAND WITH SLOT NUMBER = R TRANSITION TO READY WITH MATCHING SLOT-MARKER
CONDITIONS LEGEND:
ISO/IEC 14443 Type B-Compliant
1Kb Memory Fob
______________________________________________________________________________________ 15
Vista de página 14
1 2 ... 10 11 12 13 14 15 16 17 18 19 20 ... 24 25

Comentários a estes Manuais

Sem comentários