Note 1: All currents into the device are positive; all currents out of the device are negative. All voltages are referenced to device
ground, unless otherwise noted.
Note 2: ∆V
OD
and ∆V
OC
are the changes in V
OD
and V
OC
, respectively, when the DI input changes state.
Note 3: The short-circuit output current applies to peak current just prior to foldback-current limiting; the short-circuit foldback output
current applies during current limiting to allow a recovery from bus contention.
Note 4: Capacitive load includes test probe and fixture capacitance.
Note 5: Shutdown is enabled by bringing RE high and DE low or by bringing SHDN high. If the enable inputs are in this state for less
than 50ns, the device is guaranteed not to enter shutdown. If the enable inputs are in this state for at least 800ns, the device
is guaranteed to have entered shutdown.
MAX3465–MAX3469
+5V, Fail-Safe, 40Mbps, Profibus RS-485/
RS-422 Transceivers
4 _______________________________________________________________________________________
ELECTRICAL CHARACTERISTICS (continued)
(V
CC
= +5V ±5%, T
A
= T
MIN
to T
MAX
, unless otherwise noted. Typical values are at V
CC
= +5V and T
A
= +25°C.) (Note 1)
Recei ver O utp ut S kew
|t
PLH
-
t
PHL
|
Figure 10, C
L
= 15pF, RXP = GND or
floating (Note 4)
2ns
Receiver Enable to Output Low t
ZL
Figures 8 and 11, R
L
= 1kΩ, C
L
= 15pF,
S1 closed (Note 4)
30 ns
Receiver Enable to Output High t
ZH
Figures 8 and 11, R
L
= 1kΩ, C
L
= 15pF,
S2 closed (Note 4)
30 ns
Receiver Disable Time from Low t
LZ
Figures 8 and 11, R
L
= 1kΩ, C
L
= 15pF,
S1 closed (Note 4)
30 ns
Receiver Disable Time from High t
HZ
Figures 8 and 11, R
L
= 1kΩ, C
L
= 15pF,
S2 closed (Note 4)
30 ns
Time to Shutdown t
SHDN
(Note 5) 50
Typical Operating Characteristics
(V
CC
= +5V, T
A
= +25°C, unless otherwise noted.)