MAX6625/MAX6626
9-Bit/12-Bit Temperature Sensors with
I
2
C-Compatible Serial Interface in a SOT23
_______________________________________________________________________________________ 3
ELECTRICAL CHARACTERISTICS (continued)
(+3V ≤ V
S
≤ +5.5V, T
A =
-55°C to +125°C, unless otherwise noted.)
Note 2: Guaranteed by design and characterization to ±5 sigma.
Note 3: Quantization error not included in specifications for temperature accuracy.
Note 4: Output current should be minimized for best temperature accuracy. Power dissipation within the MAX6625/MAX6626 will
cause self-heating and temperature drift; see Thermal Considerations section.
Note 5: A master device must provide a hold time of at least 300ns for the SDA signal in order to bridge the undefined region of
SCL’s falling edge.
Note 6: C
B
= total capacitance of one bus line in pF. Tested with C
B
= 400pF.
Note 7: Input filters on SDA, SCL, and ADD suppress noise spikes less than 50ns.
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
Input High Leakage Current I
IH
V
IN
= +5V ±1 µA
Input Low Leakage Current I
IL
V
IN
= 0 ±1 µA
Input Capacitance C
IN
10 pF
Output Low Voltage V
OL
I
OL
= 3mA 0.4 V
Output High Current I
OH
V
OH
= 5V 1 µA
I
2
C-COMPATIBLE TIMING
Serial Clock Frequency f
SCL
DC 400 kHz
Bus Free Time Between STOP
and START Conditions
t
BUF
1.3 µs
START Condition Hold Time t
HD:STA
0.6 µs
STOP Condition Setup Time t
SU:STO
0.6 µs
Clock Low Period t
LOW
1.3 µs
Clock High Period t
HIGH
0.6 µs
Data Setup Time t
SU:DAT
100 ns
Data Hold Time (Note 5) t
HD:DAT
0 0.9 µs
Maximum Receive SCL/SDA
Rise Time (Note 6)
t
R
300 ns
Minimum Receive SCL/SDA
Rise Time (Note 6)
t
R
20 +
0.1C
B
ns
Maximum Receive SCL/SDA
Fall Time (Note 6)
t
F
300 ns
Minimum Receive SCL/SDA
Fall Time (Note 6)
t
F
20 +
0.1C
B
ns
Transmit SDA Fall Time
(Note 6)
t
F
C
B
= 400pF, I
O
= 3mA
20 +
0.1C
B
250 ns
Pulse Width of Suppressed
Spike (Note 7)
t
SP
50 ns
Figure 1. Serial Bus Timing
SCL
SDA
t
F
t
LOW
t
SU:DAT
t
HD:STA
t
HD:DAT
t
SU:STO
t
BUF
t
HIGH
t
R
Comentários a estes Manuais